Ring Blower GREENCO 2RB-513-1HY99 Series The performance curves are valid for pumping air at 15°C. at the inlet flanges with an air pressure of 1.013mbar and a tolerance of ±10%.The total pressure differences are valid up to an intake and ambient temperatrue of 25°C.
Blower GREENCO Single Stage Belt Drive 2RB-513-1HY99 Series
The performance curves are valid for pumping air at 15°C. at the inlet flanges with an air pressure of 1.013mbar and a tolerance of ±10%.The total pressure differences are valid up to an intake and ambient temperatrue of 25°C.
MODEL | Rated Speed | Rated Power | Max Air Flow | Max Vacuum | Max Pressure | Sound-Level | Weight |
RPM | KW | m3/h | mbar | mbar | dB(A) | Kg | |
GREENCO 2RB-513-1HY99-1 | 3000 | 1.3 | 210 | -170 | 170 | 64 | 11 |
3600 | 1.5 | 255 | -150 | 140 | 70 | ||
4200 | 1.75 | 300 | -130 | 100 | 72 | ||
5000 | 2.1 | 350 | -70 | 60 | 75 | ||
GREENCO 2RB-513-1HY99-2 | 3000 | 1.6 | 210 | -200 | 190 | 64 | |
3600 | 2.05 | 255 | -220 | 210 | 70 | ||
4200 | 2.3 | 300 | -180 | 170 | 72 | ||
5000 | 2.6 | 350 | -130 | 120 | 75 | ||
GREENCO 2RB-513-1HY99-3 | 3000 | 2.2 | 210 | -220 | 270 | 64 | |
3600 | 2.55 | 255 | -260 | 290 | 70 | ||
4200 | 3 | 300 | -300 | 270 | 72 | ||
5000 | 3.8 | 350 | -270 | 240 | 75 |