Ring Blower GREENCO 2RB-413-1HY99 Series The performance curves are valid for pumping air at 15°C. at the inlet flanges with an air pressure of 1.013mbar and a tolerance of ±10%.The total pressure differences are valid up to an intake and ambient temperatrue of 25°C.
Blower GREENCO Single Stage Belt Drive 2RB-413-1HY99 Series
The performance curves are valid for pumping air at 15°C. at the inlet flanges with an air pressure of 1.013mbar and a tolerance of ±10%.The total pressure differences are valid up to an intake and ambient temperatrue of 25°C.
MODEL | Rated Speed | Rated Power | Max Air Flow | Max Vacuum | Max Pressure | Sound-Level | Weight |
RPM | KW | m3/h | mbar | mbar | dB(A) | Kg | |
GREENCO 2RB-413-1HY99-1 | 3000 | 0.85 | 150 | -160 | 160 | 63 | 7.5 |
3600 | 0.95 | 180 | -160 | 160 | 64 | ||
4200 | 1.3 | 220 | -180 | 180 | 68 | ||
5000 | 1.5 | 250 | -140 | 130 | 74 | ||
GREENCO 2RB-413-1HY99-2 | 3000 | 1.3 | 150 | -170 | 200 | 63 | |
3600 | 1.5 | 180 | -210 | 200 | 64 | ||
4200 | 1.75 | 220 | -210 | 190 | 68 | ||
5000 | 2.1 | 250 | -190 | 190 | 74 |