Ring Blower GREENCO 2RB-213-1HY99 Series The performance curves are valid for pumping air at 15°C. at the inlet flanges with an air pressure of 1.013mbar and a tolerance of ±10%.The total pressure differences are valid up to an intake and ambient temperatrue of 25°C.
Blower GREENCO Single Stage Belt Drive 2RB-213-1HY99 Series
The performance curves are valid for pumping air at 15°C. at the inlet flanges with an air pressure of 1.013mbar and a tolerance of ±10%.The total pressure differences are valid up to an intake and ambient temperatrue of 25°C.
MODEL | Rated Speed | Rated Power | Max Air Flow | Max Vacuum | Max Pressure | Sound-Level | Weight |
RPM | KW | m3/h | mbar | mbar | dB(A) | Kg | |
GREENCO 2RB-213-1HY99 | 3000 | 0.7 | 80 | -130 | 130 | 53 | 5.5 |
3600 | 0.83 | 100 | -160 | 160 | 56 | ||
4200 | 0.95 | 120 | -170 | 170 | 60 | ||
5000 | 1.1 | 140 | -180 | 170 | 62 |
Reviews
There are no reviews yet.